Home Matteo Emanuele Fiasca Confidential meeting
Luxury boutique with an anti-intrusion fog generator activated between the display cases

The first
obstacle.

A good alarm warns; a good door or window buys the time for the warning to be of use.

Doors and windows are the first obstacle facing anyone who wants to get into a house. A good alarm warns; a good door or window buys the time for the warning to be of use. Yet they are often chosen for appearance, thermal insulation and price, and burglar resistance comes last, when the specification is already closed.

This article is a guide for architects, contractors and clients: what to ask the door and window supplier before signing, so that security can be checked on paper and not just promised.

Resistance classes

In Europe the burglar resistance of doors, windows, grilles and shutters is measured under the standard EN 1627, which sets increasing classes called RC, from RC1 to RC6. Each class corresponds to a type of attacker and tool and to a minimum resistance time in the laboratory: the low classes stop improvised attempts with simple tools, the high ones organised attacks with heavy tools.

The class needed is not decided by the catalogue but by the risk analysis: what needs protecting, how long it takes for someone to arrive, how exposed that point of the house is. A high-class front door makes no sense if the French window at the back is of a much lower class.

The certificate covers the whole assembly, not the part

A resistance class is obtained in the laboratory by a precise assembly: leaf, frame, hardware, lock, glass, fixings. If even one of these elements changes on site, the declared class is no longer guaranteed. That is why it is worth asking for the test report or certificate describing exactly the configuration tested, and checking that the product delivered matches it.

Installation is part of the resistance

A certified door or window that is badly installed resists far less than it promises. Fixing to the wall, the type of anchors and the filling between frame and wall are specified by the manufacturer precisely because they affect the test. It is worth asking for the installation instructions for that class, and for installation to be done by someone who knows them, with a final declaration.

The glass

In a security window the glass must match the rest. Glass also has resistance classes, set by the standard EN 356: laminated glass of a suitable class is not breached by a single blow and holds the fragments together. It must be requested in writing, because from outside security glass and ordinary glass look the same.

The points that get forgotten

French windows and sliding doors. Large glazed surfaces onto the garden, often in less visible areas: they are among the routes most used by people who break into a villa.

Garage and service doors. The garage door and the door connecting it to the house are often much weaker than the main entrance.

Basements, skylights, bathroom windows. Small openings considered out of reach, until someone reaches them.

Shutters. A security roller shutter or a certified grille can protect at night or during absences without replacing the window, if it too has a suitable class.

Doors, windows and alarm together

The right moment to decide is when the doors and windows are chosen, because that is when alarm contacts can be built into the frame, invisible and protected, and cable routes planned. Adding them later means visible sensors and compromises. I write about this more generally in Security before construction.

What to ask, in short

The resistance class of each door and window, chosen for the risk and not from the price list. The test report or certificate for the exact configuration. The installation instructions for that class and who will follow them. The class of the glass. Provision for the alarm contacts. The same questions for garage, service doors, shutters and grilles.

I work with architecture firms and contractors precisely to bring these choices into the design: For architects and builders. The first consultation is free and confidential: how it works.

Frequently asked questions

What does RC mean on a door or window?

It is the burglar resistance class under the European standard EN 1627, from RC1 to RC6. The higher it is, the more organised and equipped the attack the product resists.

Which class does a villa need?

It depends on the risk: what needs protecting, how exposed that point of the house is and how long it takes for someone to arrive. The analysis decides, not the catalogue.

Is buying a certified product enough?

No. The class applies only to the configuration tested in the laboratory and only if installation follows the manufacturer’s instructions.

Can windows be protected without replacing them?

Often yes, with security roller shutters or grilles of a suitable class, together with alarm contacts.

Italiano · Deutsch · Español

Request a confidential meeting

All insights